Search results for "Intraobserver reliability"

showing 2 items of 2 documents

Cephalometric measurements from 3D reconstructed images compared with conventional 2D images

2011

Abstract Objective: To assess whether the values of different measurements taken on three-dimensional (3D) reconstructions from cone-beam computed tomography (CBCT) are comparable with those taken on two-dimensional (2D) images from conventional lateral cephalometric radiographs (LCRs) and to examine if there are differences between the different types of CBCT software when taking those measurements. Material and Methods: Eight patients were selected who had both an LRC and a CBCT. The 3D reconstructions of each patient in the CBCT were evaluated using two different software packages, NemoCeph 3D and InVivo5. An observer took 10 angular and 3 linear measurements on each of the three types o…

AdultMale2d imagesAdolescentCephalometryRadiographyDentistryOrthodonticsComputed tomographyImage processingMandibleYoung AdultImaging Three-DimensionalImage Processing Computer-AssistedMaxillamedicineHumansNasal BoneSella TurcicaChildMathematicsObserver VariationOrthodonticsmedicine.diagnostic_testPalatebusiness.industryIntraobserver reliabilityReproducibility of ResultsOriginal ArticlesCone-Beam Computed TomographyIncisorFaceMandibular planeFemalebusinessObserver variationSoftwareThe Angle Orthodontist
researchProduct

Reliability of Y-Balance Test y Wight Bearing Lunge Test for the clinical-functional evolution of plantar fasciitis

2018

[Resumen] Objetivos: Los objetivos de nuestro estudio han sido determinar en pacientes con FP unilateral la fiabilidad intraobservador del instrumento Y- Balance Test (YBT) y la prueba Wight Bearing Lunge Test (WBLT) medida con el inclinómetro de un telefono movil inteligente. Métodos: Estudio transversal y observacional, realizado con 16 pacientes (9 mujeres y 7 hombres). Resultados: Los resultados obtenidos revelan una excelente fiabilidad relativa intraobservador. El YBT mostró un CCI de 0’946; mientras que las medidas con inclinómetro obtuvieron un CCI de 0’992. En el YBT se apreció una asociación de variables estadísticamente significativa en la dirección posteromedial (p=0’004) y en e…

OrthodonticsRelative reliabilitybusiness.industryFootIntraobserver reliabilityKnee flexionPiePlantar fasciitisNormal valuesLower limbEvaluación físicaRango de movimientoPhysical examinationMedicinePlantar fasciitisIn patientmedicine.symptombusinessFascitis plantarRange of motion
researchProduct